Frequently used NVM parameters for BIZPRESS13R (Diagnosis mode > DC131 NVM)
|
|||
NVM NUMBER
|
DEFAULT
|
DESCRIPTION
|
|
LONGER LIFETIME OF TONERS (WEAKER COLOR)
|
|
||
752-884
|
10
|
Y toner feeding frequency (10 = 1ms), increase it for longer toner lifetime
|
|
752-885
|
10
|
M toner feeding frequency (10 = 1ms), increase it for longer toner lifetime
|
|
752-886
|
10
|
C toner feeding frequency (10 = 1ms), increase it for longer toner lifetime
|
|
752-887
|
10
|
K toner feeding frequency (10 = 1ms), increase it for longer toner lifetime
|
|
MANUAL ADJUSTMENT OF FUSING TEMPERATURE
|
|
||
744-035
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-036
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-169
|
165
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-170
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-171
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-172
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-173
|
160
|
Temperature setting of fuser at Medium temperature mode (Normal1~3)
|
|
744-174
|
160
|
setting of fuser at Medium temperature mode (Normal1~3)
|
|
ACCUMULATED ERROR RECORDS CAN GENERATE FUSER ERROR AGAIN
|
|
||
744-001
|
0~4
|
Error Detection Flag. Please change it into 0 to delete fault records.
|
|
ADJUSTMENT OF WARMING UP TIME (WHEN WEATHER IS COLD OR FUSING PARTS REPLACED PARTLY)
|
|
||
744-547
|
30
|
To prevent 010-376 error, increase warming up time to 50
|
|
744-548
|
35
|
To prevent 010-376 error, increase warming up time to 45
|
|
744-549
|
20
|
To prevent 010-376 error, increase warming up time to 50
|
|
744-550
|
30
|
To prevent 010-376 error, increase warming up time to 45
|
|
SETUP STEP VALUE OF USER VOLTAGE OFFSET (1~16 OFFSET STEP BIAS)
|
|
||
747-019
|
200
|
0~500 (step value when offset < 6=norminal)
|
|
747-020
|
200
|
0~500 (step value when offset > 6=norminal)
|
|
BACKGROUND VOLTAGE ADJUSTMENT (INCREASE IT WHEN BACKGROUND IS DIRTY)
|
|
||
753-090
|
110
|
Y background voltage (the higher the lighter). Set 120~130 for less transfer.
|
|
753-091
|
110
|
M background voltage (the higher the lighter). Set 120~130 for less transfer.
|
|
753-092
|
110
|
|
|
753-093
|
110
|
K background voltage (the higher the lighter). Set 120~130 for less transfer.
|
|
TONER MIXING FREQUENCY OF DEVELOPER (THE LOWER THE MORE FREQUENT)
|
MUST!
|
||
741-028
|
65970
|
35970 or even 32000 (3 times higher mixing speed of developing powder)
|
|
MAX. LIFETIME CHANGE FOR CONSUMABLES
|
|
||
954-820
|
48000000
|
99999999, belt lifetime increase
|
|
954-821
|
16000000
|
32000000, 2nd transfer roller lifetime increase
|
|
954-822
|
16000000
|
32000000, cleaning blade lifetime increase
|
|
954-830
|
480000
|
1000000, developing house Y lifetime increase
|
|
954-831
|
480000
|
1000000, developing house M lifetime increase
|
|
954-832
|
480000
|
1000000, developing house C lifetime increase
|
|
954-833
|
480000
|
1000000, developing house K lifetime increase
|
|
954-834
|
480000
|
1000000, developing agent Y lifetime increase
|
|
954-835
|
480000
|
1000000, developing agent M lifetime increase
|
|
954-836
|
480000
|
1000000, developing agent Clifetime increase
|
|
954-837
|
480000
|
1000000, developing agent K lifetime increase
|
|
954-850
|
36000000
|
99999999, fuser lifetime increase
|
|
DEVELOPER CALIBRATION FREQUENCY ADJUSTMENT
|
MUST!
|
||
752-029~052
|
1000
|
The correction frequency of the developing chamber, set into 5.
Lower value means more frequent calibration in developer. Min. 2.
|
|
PRINTING LENGTH SCALING ADJUSTMENT (LARGER VALUE = SLOWER SPEED = SHORTER LENGTH)
|
|
||
744-595
|
17800
|
Speed of fuser motor 1 (57 per 1mm), 17886 = -1.5mm / m
|
|
744-596
|
17800
|
Speed of fuser motor 2 (57 per 1mm), 17886 = -1.5mm / m
|
|
744-597
|
17800
|
Speed of fuser motor 3 (57 per 1mm), 17886 = -1.5mm / m
|
|
744-598
|
17800
|
Speed of fuser motor 4 (57 per 1mm), 17886 = -1.5mm / m
|
|
744-599
|
17800
|
Speed of fuser motor 5 (57 per 1mm), 17886 = -1.5mm / m
|
|
744-600
|
17800
|
Speed of fuser motor 6 (57 per 1mm), 17886 = -1.5mm / m
|
|
741-042
|
15848
|
Speed of main motor 1 (50 per 1mm), 15924 = -1.5mm / m
|
|
741-044
|
15848
|
Speed of main motor 2 (50 per 1mm), 15924 = -1.5mm / m
|
|
741-045
|
15848
|
Speed of main motor 3 (50 per 1mm), 15924 = -1.5mm / m
|
|
741-062
|
-32
|
Fine adju value of main motor, set into 0
|
|
ADC/TRC SENSOR ON/OFF (OFF WHEN COLOR CHANGES TOO SENSITIVELY)
|
|
||
754-001
|
1
|
ADC Tone Control Switch, turn off = 0
|
|
754-002
|
1
|
Tonal Reproduction Curve (TRC) calibration, turn off = 0
|
|
752-799
|
1
|
Delta ATC Target Overall Correction switch, turn off = 0
|
|
IGNORE ENVIRONMENT SENSOR DETECTION (LESS COLOR CHANGE)
|
|
||
746-001
|
0
|
Resistance Detection Control Switch, turn off = 1
|
|
746-016
|
2000
|
2nd BTR Final Output (Side1), set 4000 (-2v) to reduce environment effect
|
|
746-017
|
2000
|
2nd BTR Final Output (Side2), set 4000 (-2v) to reduce environment effect
|
|
746-036~047
|
2000
|
2nd BTR Transfer Bias Output Fixed Val, set 4000 (-2v) to reduce env. effect
|
|
KEEP ORIGINAL VALUES OF ATC SETTINGS AFTER IOT INITIALIZATION
|
|
||
752-395
|
1024
|
ATC Ave. Sensitivity Correc. Coef [Y]
|
|
746-016
|
1024
|
ATC Ave. Sensitivity Correc. Coef [M]
|
|
746-017
|
1024
|
ATC Ave. Sensitivity Correc. Coef [C]
|
|
746-036~047
|
1024
|
ATC Ave. Sensitivity Correc. Coef [K]
|
|
746-001
|
0
|
ATC Ave. Sensitivity Cor. Offset [Y]
|
|
746-016
|
0
|
ATC Ave. Sensitivity Cor. Offset [M]
|
|
746-017
|
0
|
ATC Ave. Sensitivity Cor. Offset [C]
|
|
746-036~047
|
0
|
ATC Ave. Sensitivity Cor. Offset [K]
|
|
746-001
|
55
|
ATC_ Double Average [Y]
|
|
746-016
|
55
|
ATC_Double Average [M]
|
|
746-017
|
55
|
ATC_Double Average [C]
|
|
746-036~047
|
55
|
ATC_Double Average [K]
|
|
Caution :
|
The factory value of each machine is different. After IOT initializing, keep original values.
|
|
|
DEVELOPER CHAMBER POWDER AMOUNT CHECK (620 > CURRENT VAL > DEFAULT, LESS POWDER IN DEV.)
|
|
||
752-774(Y)
|
596
|
ATC reference value [Y], set 480 or even 450 to get darker color
|
|
752-775(M)
|
596
|
ATC reference value [M], set 480 or even 450 to get darker color
|
|
752-776(C)
|
596
|
ATC reference value [C], set 480 or even 450 to get darker color
|
|
752-777(K)
|
596
|
ATC reference value [K], set 480 or even 450 to get darker color
|
|
752-778(Y)
|
596
|
ATC current value [Y]
|
|
752-779(M)
|
596
|
ATC current value [M]
|
|
752-780(C)
|
596
|
ATC current value [C]
|
|
752-781(K)
|
596
|
ATC current value [K]
|
|
Caution :
|
adjustment of ATC reference value is temporary method. Fill powder or change developer.
|
|
|
|
|
|
|
Calibration of color registration for BIZPRESS13R (Diagnosis mode > DC671, 673, 675)
|
|||
Run DC671(Registration measurement cycle checking), DC673(Registration control sensor cycle checking), DC675(Registration control setup cycle checking) to fix color registration error
|
|
||
|
|
|
|
Consumable Lifetime Initialization for BIZPRESS13R (Diagnosis mode > DC135 HFSI Counter)
|
|||
NVM NUMBER
|
DEFAULT
|
DESCRIPTION
|
|
954-820
|
current value
|
belt lifetime initialization to 0
|
|
954-850
|
current value
|
fuser lifetime initialization to 0
|
|
954-830
|
current value
|
developing house Y lifetime initialization to 0, run DC950, DC949
|
|
954-831
|
current value
|
developing house M lifetime initialization to 0, run DC950, DC949
|
|
954-832
|
current value
|
developing house C lifetime initialization to 0, run DC950, DC949
|
|
954-833
|
current value
|
developing house K lifetime initialization to 0, run DC950, DC949
|
|
Caution :
|
Do this after new consumable replacement!
|
|
|
|
|
|
|
ATC setup after developing unit replacement for BIZPRESS13R (Diagnosis > DC950 > DC949)
|
|||
Run DC950 and adjust ATC values of each CMYK according to new developer cartridge barcode number
Run DC949 by pressing ON for each CMYK to rujn ATC initialization process.
|
|
||
|
|
|
|
IOT (NVM settings) initialization for BIZPRESS13R (Diagnosis > DC301)
|
|||
Run DC950 and adjust ATC values of each CMYK according to new developer. After initialization, please set the value in 741-028 to 32000 and 752-029~052 to 5! |
|